Radiation Measurement with Data Acquisition Using LabVIEW

Radiation Measurement with Data Acquisition Using LabVIEW

Original Research ArticleMar 15, 2023Vol. 23 No. 5 (2023) 10.55003/cast.2023.05.23.004

Abstract

Radiation monitoring and measurement are important for radiation safety. Such monitoring and measurement must be carried out in order to investigate workplace conditions and individual exposures, to ensure that radiological conditions in the workplace are acceptable, safe, and satisfactory, and to keep records of radiation monitoring over a long period of time in accordance with regulations or as good practice. However, radiation monitoring instruments and system are expensive. A cost-effective radiation monitoring system using Geiger Muller (GM) radiation detector was developed. A high voltage generation circuit and data acquisition were implemented using LabVIEW software. The cost-effective radiation monitoring system is easy to use, and it can detect radiation, analyzed and record the data in a personal computer. This newly developed system is simple and can provide the radiation dose data for further analysis. An experiment was conducted to compare and calibrate the collected data at the Secondary Standard Dosimetry Laboratory (SSDL). The result shows that the new developed GM detector provides good correlation between counts per minute (cpm) and dosage units, which is good characteristic of a radiation counting system.

Keywords: GM counter; high voltage generation radiation detection; data acquisition

*Corresponding author: Tel.: (+662) 4019889 Ext.5211

                                             E-mail: kanokrat@tint.or.th

 

References

1
Quraishi, M.H, Hoque, M.A, Begum, A. and Alam, M.J., 2014. Computer based radioactivity measurement with acquisition and monitoring radiation data using LabVIEW. 2014 International Conference on Informatics, Electronics and Vision (ICIEV), Dhaka, Bangladesh, 23-24 May, 2014, pp. 1-4.
2
Gandhiraj, P. and Jayapandian, J., 2014. An embedded read-out for GM counter. International Journal of Instrumentation Technology, 1(13), 228-240.
3
Poole, I., 2001. Diode Voltage Multiplier Circuit. [online] Available at: http://www.radioelectronics.com/info/circuits/diode_voltage_multiplier/diode_volt_mult.
4
Weiss, C., Al-Frouh, K. and Anjak, O., 2011. Automation of radiation dosimetry using PTW dosemeter and LabVIEW. Nuclear Instruments and Methods in Physics Research Section: A, 654(1), 649-652.
5
Rajaram, V., Rathod, H. and Kholi, V.R., 2016. LABVIEW based data acquisition and automation. International Journal on Recent and Innovation Trends in Computing and Communication, 4(4), 406-408.

Author Information

Udomsak Keawmorakot

Reactor Center, Thailand Institute of Nuclear Technology (Public Organization), Bangkok, Thailand

Udomsak Keawmorakot

Reactor Center, Thailand Institute of Nuclear Technology (Public Organization), Bangkok, Thailand

Udomsak Keawmorakot

Reactor Center, Thailand Institute of Nuclear Technology (Public Organization), Bangkok, Thailand

Udomsak Keawmorakot

Reactor Center, Thailand Institute of Nuclear Technology (Public Organization), Bangkok, Thailand

Udomsak Keawmorakot

Reactor Center, Thailand Institute of Nuclear Technology (Public Organization), Bangkok, Thailand

Udomsak Keawmorakot

Faculty of Industrial Technology, Chitralada Technology Institute, Bangkok, Thailand

About this Article

Current Journal

Vol. 23 No. 5 (2023)

Type of Manuscript

Original Research Article

Keywords

GM counter;
high voltage generation radiation detection;
data acquisition

Published

15 March 2023

DOI

10.55003/cast.2023.05.23.004

Current Journal

Journal Cover
Vol. 23 No. 5 (2023)

Search

Latest Articles

Original Research Article
Mar 12, 2025

Comparison of Early and Late Season Phytochemical Content in Mon Thong Durian Cultivar (Durio zibethinus Murray)

Original Research Article
Mar 12, 2025

Diversity of Macrofungi in the Nature Trail of Namtok Phlio National Park, Chanthaburi Province, Thailand

Original Research Article
Mar 12, 2025

Selection of Stable Rice Genotypes through WAASB and MTSI Indices

Original Research Article
Mar 12, 2025

Sensitivity of Phytophthora palmivora Causing Durian Diseases to Metalaxyl-M and Dimethomorph in Southern and Eastern Thailand