Non-invasive Blood Glucose Measurement Using Near-infrared Spectroscopy and Microcontroller Equipment

Non-Invasive Blood Glucose Measurement Using Near-Infrared Spectroscopy and Microcontroller Equipment

Original Research ArticleDec 1, 2025Online First Articles https://doi.org/10.55003/cast.2025.266010

Abstract

This study focuses on the development of modern, non-invasive equipment for measuring blood glucose levels using near-infrared (NIR) spectroscopy with a transmitter of 940 nm wavelength light emitting diode (LED). The aim is to eliminate the need for invasive methods and provide greater convenience for patients. The equipment operates by emitting infrared spectrum from a high-speed LED VLSB3940, which is passed through the patient's fingertip and receive by a BPX 65 photodiode receiver. The received signal is converted into voltage by the BPX65 photodiode. The output voltage from the BPX65, which varies with glucose concentration in the blood, is then amplified by an operational amplifier (op-amp) circuit. The amplified voltages are collected by an Arduino microcontroller that is interfaced with a touch screen display. A corresponding C-Arduino language program controls all processes and displays the measurement results on the screen. The study concludes that the near-infrared spectrum can effectively transmit signals through the blood glucose in the fingertip, yielding results comparable to the old invasive method. The linear regression of invasive and non-invasive blood glucose measurements had R2 values of 0.99 and 0.82, respectively. The plot of Clarke Error Grid Analysis (CEGA) showed that most of points were in zone A, indicating high accuracy. However, further development of the system is recommended, including the exploration of alternative transmitters of 1550 nm wavelength, better receivers, and circuits to optimize the equipment for commercial uses.

non-invasive blood glucose
near-infrared spectroscopy
microcontroller

How to Cite

Jairuk, U. ., Phunpueok, A. ., & Choosakul, N. . (2025). Non-invasive Blood Glucose Measurement Using Near-infrared Spectroscopy and Microcontroller Equipment. Current Applied Science and Technology, e0266010. https://doi.org/10.55003/cast.2025.266010

References

  • Al-Hafidh, M. H., Glidle, A., Wilson, R., Kelly, A. E., Reboud, J., & Cooper, J. M. (2019). Multireflection polarimetry in microfluidics. IEEE Sensors Letters, 3(10), 1-4. https://doi.org/10.1109/lsens.2019.2943688
  • Beutler, E., & Waalen, J. (2006). The definition of anemia: what is the lower limit of normal of the blood hemoglobin concentration? Blood, 107(5), 1747-1750. https://doi.org/10.1182/blood-2005-07-3046
  • Boustany, N. N., Boppart, S. A., & Backman, V. (2010). Microscopic imaging and spectroscopy with scattered light. Annual Review of Biomedical Engineering, 12(1), 285-314. https://doi.org/10.1146/annurev-bioeng-061008-124811
  • Busher, J. T. (1990) Serum albumin and globulin. In H. K. Walker, W. D. Hall, & J. W. Hurst (Eds.). Clinical methods: The history, physical, and laboratory examinations (3rd Ed., pp. 497-499). Butterworths. https://www.ncbi.nlm.nih.gov/books/NBK204/
  • Cengiz, E., & Tamborlane, W. V. (2009). A tale of two compartments: interstitial versus blood glucose monitoring. Diabetes Technology and Therapeutics, 11(S1), S-11-S-16. https://doi.org/10.1089/dia.2009.0002

Author Information

Umpon Jairuk

Division of Physics, Faculty of Science and Technology, Rajamangala University of Technology Thanyaburi, Pathumthani, 12110, Thailand

Akapong Phunpueok

Division of Physics, Faculty of Science and Technology, Rajamangala University of Technology Thanyaburi, Pathumthani, 12110, Thailand

Nithiwatthn Choosakul

Division of Physics, Faculty of Science and Technology, Rajamangala University of Technology Thanyaburi, Pathumthani, 12110, Thailand

About this Article

Journal

Online First Articles

Type of Manuscript

Original Research Article

Published

1 December 2025